a2388082483 发表于 2020-9-14 19:28:36

海尔KF(Rd)-60LW/48/50/71/70/45/G(ZXF)(ZYF)/Z2/K2/G空调故障维修代码表

海尔KF(Rd)-60LW/48/50/71/70/45/G(ZXF)(ZYF)/Z2/K2/G空调故障维修代码表
KF(Rd)-60LW/G(ZXF) KF(Rd)-50LW/G(ZXF) KF(Rd)-50LW/G(ZYF) KF(Rd)-60LW/G(ZYF) KF(Rd)-71LW/G(ZXF)KF(Rd)-71LW/G(ZYF) KF(Rd)-60LW/K(ZXF) KF(Rd)-58LW/K(ZXF) KF(Rd)-68LW/K(ZXF)KF(Rd)-48LW/K(F)KF(Rd)-48LW/K(XF) KF(Rd)-48LW/K(YF)KF(Rd)-58LW/K(F)KF(Rd)-58LW/K(XF) KF(Rd)-58LW/K(YF)KF(Rd)-68LW/K(F)KF(Rd)-68LW/K(XF) KF(Rd)-68LW/K(YF)KF(Rd)-71LW/K(F)KF(Rd)-71LW/K(XF) KF(Rd)-71LW/K(YF)    KFRd-50LW/V(ZXF)   KFRd-60\71LW/V(ZXF)KFRd48,50LW/Z2KF-48LW/Z2KFRd-58LW/Z2KF-58LW/Z2KFRd-71LW/Z2         KF-71LW/Z2 KF-45LW/Z2 KFRd-48LW/K2 KF-48LW/K2KFRd-58LW/K2 KF-58LW/K2 KFRd-68LW/K2 KF-68LW/K2 KFRd-50、60、71LW/VA(ZXF)KF(Rd)-50LW/G(ZXF) KF(Rd)-50LW/G(ZYF)KF(Rd)-60LW/G(ZXF) KF(Rd)-60LW/G(ZYF) KF(Rd)-71LW/G(ZXF)KF(Rd)-71LW/G(ZYF) KFR-70LW/Z(S)KF(Rd)-48LW/Z   KF(Rd)-58LW/ZKF(Rd)-70LW/Z KF(Rd)-70LW/Z(S)KFRD-75LW/G(ZXF)KFRD-75LW/@(F)
E1室内环境温度传感器保护E11.查室内环境温度传感器是否短路或开路。2.换内板
E2室内盘管温度传感器保护E21.查室内盘管温度传感器是否短路或开路。2.换内板
压力保护E6-
E7电源低电压保护E71.查内板电阻R2是否烧坏。若烧坏,换电阻即可。2.查内板TV-01原副边线圈是否断路,若断路,则换TV-01。
E8面板与内机通信故障E81.查内板电阻R13是否烧坏。若烧坏,换电阻即可。2.查内板L2、L3线圈是否断路,若断路,则换L2、L3即可。3.根据实际电网情况,考虑将L2、L3分别用短接线短接。
不开机-1.查变压器是否烧坏。正常则进入下一步。2.查电源滤波器LX102是否腿断,若是换LX102。3.查保险丝烧否,若是,则换保险丝。4查+5V,+12V电源正常,内电脑板在测短接内板XT2端子,仍不工作,可判定单片机损坏,换内电脑板。
制热外风机时开时停-属空调器正常保护,向用户解释清楚。
不制冷-压缩机继电器坏。
压缩机工作不制热-换向电磁阀继电器坏。
外风机不转-风机继电器坏。
内风机不转-内板风机输出继电器坏。
压缩机故障诊断-传感器故障-四通电磁阀故障-室内机-外机

页: [1]